The new 1280 × 1024 HD thermal imaging camera delivers four times the pixel count of VGA A-Series models, enabling researchers to capture greater thermal detail while retaining existing workflows, optics and infrastructure.
Teledyne FLIR has announced the launch of the A8481, a compact high-definition midwave infrared (MWIR) science camera developed for researchers and engineers seeking enhanced thermal imaging capabilities without the disruption associated with adopting a new camera platform.
Featuring a 1280 × 1024 high-operating-temperature (HOT) MWIR strained-layer superlattice (SLS) detector, the A8481 provides four times the pixel count of VGA-resolution A-Series cameras while retaining the compact form factor of the A67xx platform.
Upgrading from VGA to HD thermal imaging has traditionally involved moving to a larger camera system, often requiring changes to mounting arrangements, optics, software integration and validation procedures. The A8481 addresses these challenges by bringing HD MWIR imaging to the established compact A-Series platform, which is widely used in laboratories, testing facilities and research environments.
“The A8481 removes one of the biggest barriers to adopting HD thermal imaging,” said Matthew Hasty, Director of Product Management for Automation and Science at FLIR. “Researchers have long wanted more thermal detail without introducing the complexity of a larger camera platform. With the A8481, customers can move to 1280 × 1024 HD thermal imaging while continuing to use the same compact A-Series workflow, optics ecosystem, software environment, and integration infrastructure they already trust.”
High-Resolution Imaging for Precise Thermal Measurements
At the heart of the A8481 is a 1280 × 1024 focal plane featuring 8 µm HOT MWIR SLS technology. With thermal sensitivity below 30 mK, the camera captures detailed radiometric data to support demanding scientific and industrial measurement applications.
Users can integrate the camera into existing setups through compatibility with the FLIR Precision Optics ecosystem, established mounting interfaces, connectivity options and the FLIR Research Studio software workflow.
Connectivity options include GigE Vision, GenICam and CoaXPress, alongside precision triggering and synchronisation capabilities designed to support controlled, repeatable data acquisition.
An integrated motorised three-position filter wheel allows users to extend temperature measurement ranges, while support for motorised and manual-focus lenses, microscope optics and macro lenses provides flexibility across applications. These optical options enable researchers to maximise the number of measurement pixels covering a target, from larger assemblies to individual components and microscopic structures.
Supporting a Wide Range of Research Applications
The A8481 is designed for scientific investigation, industrial testing and advanced thermal measurement across multiple disciplines. Potential applications include electronics analysis, battery research, combustion studies, propulsion testing, non-destructive testing, materials characterisation and academic research.
Its combination of high spatial resolution, radiometric recording and microscope-compatible optics allows users to investigate thermal behaviour at different scales. Researchers can examine temperature distributions across complete systems while also analysing localised heat patterns in small components and microscopic features.
“The real advantage of the A8481 is that customers can increase the amount of thermal information they capture without disrupting established test procedures,” said Jerry Beeney, Sales Manager, R&D Science, Teledyne FLIR. “Whether they’re upgrading from an existing A-Series camera or building a new measurement system, the A8481 provides HD detail, measurement-grade data, and compatibility with the software, optics, and workflows they’ve already invested in. It delivers more insight while keeping implementation simple.”
High-Speed Recording and Analysis Capabilities
Beyond its HD imaging performance, the A8481 supports fully radiometric .ATS recording through FLIR Research Studio Professional. The software provides tools for data acquisition, analysis, collaboration and reporting, helping research teams manage thermal measurement workflows from capture through to interpretation.
For experiments involving rapid temperature changes or transient thermal events, windowed imaging modes support frame rates of up to 13,733 Hz. This capability enables researchers and engineers to capture fast-moving thermal phenomena while retaining the measurement data required for detailed scientific analysis.
A Practical Upgrade for Existing A-Series Users
The A8481 expands Teledyne FLIR’s science camera portfolio by providing a compact HD MWIR solution for organisations seeking greater thermal resolution without redesigning their existing test environments.
By combining enhanced spatial detail with established optics, software compatibility and integration options, the camera offers a practical upgrade path for existing A-Series users as well as a flexible solution for new research and measurement systems.
The Teledyne FLIR A8481 is scheduled to become available from October 2026 through the company’s global network of sales representatives and channel partners. Demonstrations and application consultations will also be available to organisations assessing HD MWIR thermal imaging for research and testing.
For further information, visit the Teledyne FLIR A-Series camera product page.